Annals of Emergency Medicine
Volume 52, Issue 5 , Pages 504-511, November 2008

Accuracy of Staff-Initiated Emergency Department Tracking System Timestamps in Identifying Actual Event Times

Presented as a poster at the Society for Academic Emergency Medicine annual meeting, May 2005, San Francisco, CA.

  • Bradley D. Gordon, MD, MS

      Affiliations

    • Regions Hospital Department of Emergency Medicine, St. Paul, MN, and the HealthPartners Research Foundation, Bloomington, MN
    • Department of Emergency Medicine, University of Minnesota Medical School, Minneapolis, MN
    • Corresponding Author InformationAddress for correspondence: Bradley D. Gordon, MD, MS, Regions Hospital, Mailstop 11102F, 640 Jackson Street, St. Paul, MN 55101; 651-254-6994, fax 651-254-5216
  • ,
  • Thomas J. Flottemesch, PhD

      Affiliations

    • Regions Hospital Department of Emergency Medicine, St. Paul, MN, and the HealthPartners Research Foundation, Bloomington, MN
  • ,
  • Brent R. Asplin, MD, MPH

      Affiliations

    • Regions Hospital Department of Emergency Medicine, St. Paul, MN, and the HealthPartners Research Foundation, Bloomington, MN
    • Department of Emergency Medicine, University of Minnesota Medical School, Minneapolis, MN

Received 19 July 2007; received in revised form 21 September 2007, 25 October 2007 and 8 November 2007; accepted 27 November 2007. published online 04 March 2008.

Study objective

Managers use timestamps from computerized tracking systems to evaluate emergency department (ED) processes. This study was designed to determine how accurately these timestamps reflect the actual ED events they purport to represent.

Methods

An observer manually timestamped patient and provider movement events during all hours. The observed timestamps were then systematically matched to equivalent timestamps collected by an active tracking system (timestamps created by staff with keyboard/mouse) and a passive tracking system (timestamps created by sensor badge worn by staff members). The deviation intervals between the matched timestamps were analyzed.

Results

The observer noted a total of 901 events; 686 (76%) of these were successfully matched to active system timestamps and 60 (6.7%) were matched to passive system timestamps. For the active system, the median event was recorded 1.8 minutes before it was observed (interquartile range 30.7 minutes before to 2.9 minutes after). Protocol execution difficulties limited the study of the passive system (low number of successfully matched events). The median event was recorded by the passive system 1.1 minutes before it was observed (interquartile range 1.3 minutes before to 0.9 minutes before) (n=60).

Conclusion

The timestamps recorded by both active and passive tracking systems contain systematic errors and nonnormal distributions. The active system had much lower precision than the passive system but similar accuracy when large numbers of active system observations were used. Medians should be used to represent timestamp and interval data for reporting purposes. Site-specific data validation should be performed before use of data in high-profile situations.

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

 Author contributions: All authors are responsible for study conceptualization and design. BDG coordinated data acquisition, drafted the article, obtained funding and supervised of the study execution. BDG and TJF performed analysis and interpretation of the data. TJF provided detailed statistical support. All authors contributed substantially to the intellectual content and critical revisions of the paper. BDG takes responsibility for the paper as a whole.

 Supervising editor: Robert L. Wears, MD, MS

 Funding and support: By Annals policy, all authors are required to disclose any and all commercial, financial, and other relationships in any way related to the subject of this article, that might create any potential conflict of interest. See the Manuscript Submission Agreement in this issue for examples of specific conflicts covered by this statement. Dr. Gordon is supported by a National Library of Medicine Early Career Development Award in Medical Informatics (K22LM008573-01).

 Reprints not available from the authors.

 Publication date: Available online March 7, 2008.

PII: S0196-0644(07)01804-5

doi:10.1016/j.annemergmed.2007.11.036

Annals of Emergency Medicine
Volume 52, Issue 5 , Pages 504-511, November 2008